  delphi series h48sv , 150w half brick family dc/dc power modules: 48v in, 3.3v/10a out the delp hi serie s h48sv half bri ck, 48 v input, sin g l e output, i s ol ated dc/ dc conv erters a r e th e latest of feri ng from a wo rld lea der in power system s tech nology an d manufa c turi n g D delt a el ectronics, inc. this prod uct famil y provide s u p to 150 wa tt s of po we r or 4 0 a of o u tput curre n t (3.3v model) in a n indust r y st anda rd footp r int. this pro duct family come s with st a n d a rd p o sitive trimming m e thod a nd u t ilize s st an dard trim value. it also come s with output trimmi ng ran ge bet wee n +10% to ? 20%. all model s are fully protecte d from abn ormal input/output volt age, current, and tem peratu r e co n d itions. t he delp hi serie s co nverters me et all safety requi re ment s with b a si c insulatio n . optio n s positive remote on/ o f f logic short pin lengths available applica t i o ns t e lecom/dat a com wir e less netw orks optical net w ork equipment server and dat a s t orage industrial/t e sting equipment featur es high ef ficiency: 89.5% @ 3.3v/ 10a size: 61.0x57.9 x 12.7mm (2.4 0?2 .28?0.50? ) s t andard footp r in t industr y st an dar d pin out fixed f r equenc y operation met a l baseplate input uvl o , out put ocp , ovp , otp basic insu lation no minimum load required 2:1 input volt age range iso 9001, t l 90 00, iso 14 001, qs 9000, o h sas 1800 1 certified manufact u ring facility ul/cul 60950 ( u s & canada ) r e cognized, and tuv (en 609 50) ce rtified ce mark meet s 73/23/eec and 9 3 /68/eec directives d a t a s h eet ds_h 48sv3 r 310 _0 815 20 06
technical specifica t i o ns (t a =25 c, airfl o w rate=300 lfm , v in =48vdc, n o m inal v o u t u n le ss ot her w ise no ted.) pa r a m e t e r notes an d conditions h48sv3r310 (s t a ndard) min . t y p . ma x . u n it s a b solute m a xi mu m ra tings inpu t v o lt ag e continuou s 8 0 v d c t r ansien t (100m s) 100ms 100 vdc operati ng ca se t e mperature t c -40 100 c s t orage t e mperatu r e -55 125 c inpu t/ou t pu t isola t i on v o lt age 1 minute 1500 vdc input cha r a c teristics operati ng inpu t v o l t age 36 48 75 vdc inpu t under -v ol t a g e lo cko ut t u rn-on v o l t age th reshold 33 34 35 vdc t u rn-o f f v o lt age th reshold 31 32 33 vdc lockout hy stere s is v o lt age 1 2 3 vdc max i mu m inpu t cur r ent 100% lo ad, 36v i n 1.3 a no-load inpu t curr ent 60 100 ma of f conv erter inpu t current 5 10 ma i n r u s h cu rr e n t (i 2 t) 0.015 a 2 s inpu t r e flec ted-r i p p le c u rren t p-p thru 12h ind u c to r , 5h z to 20mhz 15 ma inpu t v o lt ag e rippl e rejection 120 hz 65 db output ch a r a c teri sti c s outpu t v o lt age set point v i n=48v , io= i o . max, t c =25c 3.25 3.30 3.35 vdc outpu t v o lt age reg u lation ov er load io= i o , m i n to io ,m ax 3 10 mv ov er line v i n=36v to 75v 3 10 mv ov er t e mperature t c =-40c to 100c 15 50 mv t o t a l ou tpu t v o lt ag e range ov er sample loa d , li ne and temp erature 3.20 3.40 v outpu t v o lt age rip p le and noise 5hz to 20mhz ban dw id th peak- t o-pe ak full load , 1f cer a mic, 10f t a nt alum 50 100 mv rms full load , 1f cer a mic, 10f t a nt alum 15 30 mv operati ng outpu t current range 0 10 a outpu t dc cur r ent- l imit in ception outpu t v o lt age 1 0 % low 120 175 % dyn a m i c ch a r a c teri sti c s outpu t v o lt age cur r ent t r an sien t 48v , 1 0 f t an & 1 f ceramic load ca p , 0 . 1a /s posi tiv e s t ep chan ge in ou tput curre nt 50% io.m ax to 75% io .m ax 70 m v negativ e s t ep cha nge in ou tpu t curr ent 75% io.m ax to 50% io .m ax 70 mv settling t i me (w ithi n 1% v o ut nominal) 200 us t u rn-on t r an sien t s t art-up t i me, fro m on/of f con t rol 10 20 ms s t art-u p t i m e , f r o m inpu t 10 20 ms max i mu m outpu t c a p a cit a n c e full load ; 5 % ov ershoot of v out a t st ar tup 5000 f effi ci ency 100% lo ad 89.5 % 60% loa d 8 7 . 0 % i s o l at i o n c h ar ac t e r i s t i c s inpu t to outp ut 1500 vdc inpu t to c a se 1500 v d c outpu t to c a se 500 vdc isol ation re sist ance 10 m ? isol ation cap a cit a n c e 2000 pf fe a t ure ch a r acteri s ti cs sw itching freq uen cy 320 kh z on/off control, n egativ e remote on /o f f logi c logic low (module on) v on/of f at io n/o f f=1.0ma 0 0.8 v logic high (mo dule o f f) v on/of f at io n/o f f=0.0 a 18 v on /of f c ont rol, p o sit i v e r e m o te on / o f f log i c logic low (module of f) v on/of f at io n/o f f=1.0ma 0 0.8 v logic high (mo dule on) v on/of f at io n/o f f=0.0 a 18 v on /of f c u rren t (f or bo th rem o te on /o f f logi c) ion/of f at v o n/o f f=0.0v 1 ma leakage curren t (for bo th remote on /o f f logi c) logic high, v on/of f=18v 50 ua outpu t v o lt age t r i m range acro ss pin s 9 & 5 , pout Q max rated pow er -20 +10 % outpu t v o lt age re mote s ense range pout Q max rated pow er 10 % o u t p ut o v e r - v o l ta ge p r ot ec t i o n ov er full temp rang e; % o f nominal v o ut 1 15 122 130 % genera l specifica t ions mtbf io=80% of io, max ; t c =40c 3 m hour s we i g ht 5 8 g r a m s ov er-t emperature shut dow n a v erage pcb t e mp erature 1 10 c ds_h48sv3 r31 0_0 8152 006 2
electri cal characteristi cs cur ves 60 65 70 75 80 85 90 95 24 68 o u t p ut c urre n t ( a ) efficiency (% ) 1 0 36vi n 48vi n 75vi n 0. 0 1. 0 2. 0 3. 0 4. 0 5. 0 6. 0 7. 0 8. 0 9. 0 10. 0 11. 0 12. 0 24 6 8 o u t p ut c urr e n t ( a ) power dissipation (w) 1 0 36 v i n 48vi n 75vi n figure 1 : ef ficiency vs. lo ad c u rrent for mi ni mu m, n o m in al, and max i mu m in put volt age at 2 5 c. f i g u r e 2 : power dissip a tion vs. load c u r r ent f o r min i mu m, no mi nal, an d max i mu m in put volt age at 2 5 c. figure 3 : t y pical in put char acteristics at roo m temp erature (io= 10a) ds_h48sv3 r31 0_0 8152 006 3
electri cal characteristi cs cur ves for negative remote on/off logic figure 4 : t u rn-on transi ent a t full rated l o a d current (res i stive loa d ) (2 ms/di v ).v i n= 48v . t o p t r ace: v o ut; 1v/div; botto m t r ace: on/of f input: 5v/div figure 5 : t u rn-on transi ent at z e r o lo ad curre nt (2 ms/div). vi n = 4 8 v . t op t r ace: v out: 1v/div; bottom t r a c e: on/of f in put: 5v/div for positive remote on/off logic figure 6 : t u rn-on transi ent a t full rated l o a d current (res i stive load) (2 ms/di v ).v i n= 48v . t o p t r ace: v o ut; 1v/div; botto m t r ace: on/of f input: 5v/div figure 7 : t u rn-on transi ent at z e r o lo ad curre nt (2 ms/div). vi n = 4 8 v . t op t r ace: v out: 1v/div; bottom t r a c e: on/of f in put: 5v/div ds_h48sv3 r31 0_0 8152 006 4
electri cal characteristi cs cur ves figure 8 : output volt ag e re spons e to step-cha nge i n l oad current (50 % -7 5%-5 0% of ima x ; di/d t = 0.1a/ s ) .v in= 4 8v . load cap: 10 f , t antalu m cap a citor and 1 f c e ra mic cap a cito r . t op trace: v out (1 00 mv/div), bo tto m trace: io ut (5a/div). scop e me asur e m ent shou ld be ma de usi ng a bnc cabl e (len gth shorter than 20 inches). position the load b e tw een 51 mm a n d 76 mm ( 2 i n ch es and 3 i n ch e s ) from the mo dul e. f i g u r e 9 : output volt a ge re spons e to ste p -cha nge in l oad current (75 % -5 0%-7 5% of io, max; di/d t = 2.5a/ s ) . load c ap: 470 f , 35 m ? esr solid e l ec trolytic cap a cit o r and 1 f cer a mic cap a cit o r . t o p t r ace: v out ( 100 mv/d iv), bottom t r ace: iout (5a/div). scop e meas ure m e n t shou ld be ma de usin g a bn c cabl e (len gth shorter than 20 inch es). position th e load betw een 51 mm to 76 mm ( 2 inches to 3 inches) from the mo du le. figure 1 0 : t e st set-up diagr am sh ow ing measur e m ent po int s for input t e rmi nal ri ppl e cur r ent and input reflected rip ple current. note: meas ure d inp u t reflecte d-ripp le c u rrent w i th a simulat e d source ind u ct ance (l test ) of 12 h. cap a cit o r cs of fset possi ble b a tter y imp e d ance. measur e curre nt as show n ab ove. ds_h48sv3 r31 0_0 8152 006 5
electri cal characteristi cs cur ves figure 1 1 : input t e r m in al rip ple curr ent, i c , at full rated output current an d no mi nal i n p u t volt age w i th 12 h source impedance and 3 3 f elect r olytic cap a c i to r (200 ma/ d iv). figure 1 2 : in put reflected ri ppl e current, i s , through a 12 h source i n d u cto r at nomin al in put vo lt ag e an d rated l oad c u rrent (20 ma/ d iv). vo(-) vo(+) 10u 1u copper strip scope resistive load figure 1 3 : ou tput volt age no ise and ri ppl e me asur e m ent test setup ds_h48sv3 r31 0_0 8152 006 6
electri cal characteristi cs cur ves 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 0 2468 1 0 1 2 1 4 1 6 1 8 l o a d cur re nt ( a ) out p ut vol t age (v) v i n= 48v figure 1 4 : output volt a ge rippl e at no mi nal i n p u t v o ltage (v in=48v) and rated lo ad cu rrent(io= 10a) ( 20 mv/div). l oad cap a cit a nce: 1 f c e ra mic cap a citor a nd 10 f t a nt alu m cap a cit o r . ba n d w i d t h: 20 mh z . sco pe meas ure m e n t sho u l d be ma de usin g a bnc cab l e (l ength s horter than 2 0 inc h e s ). positio n the lo ad betw een 51 mm an d 76 mm (2 inch es an d 3 inch es) from th e mo du le. f i g u r e 1 5 : output volt a ge vs. load curr e n t show ing ty pical current li mit cu rves and co nve r ter shut dow n poi nt s. ds_h48sv3 r31 0_0 8152 006 7
thermal cur ves: no hea t sink figure 1 6 : case temperatur e meas ure m ent locati on. pin loc a tions a r e for referenc e only . f i g u r e 1 7 : output current vs. ambi ent temp e r ature and air velocit y (v in < 60v) figure 1 8 : output curre nt vs. ambie n t temper ature a nd a i r velocity (v in =75 v ) f i g u r e 1 9 : pow e r dissip a ti o n vs. ambie n t temp eratur e and ai r velocity h 4 8s v 3 r 3 10 ( s t a nd ar d ) o u t p u t c u r r e nt vs . a m bie n t te m p e r at ur e an d a i r v e lo ci t y @ v i n < 60 v ( e i t he r o r i e n t at ion , n o h eat si nk ) 0 1 2 3 4 5 6 7 8 9 10 11 7 5 80 85 90 95 1 0 0 105 a m bi ent t e m pera t ure ( ) output cur r ent(a ) nat u ra l c o nv ec t i o n 100 lf m 20 0lf m 3 00l fm 400 lf m 500 lf m 60 0l f m h 4 8 s v 3 r 310(s t andard) o u tput c u rr en t vs. a m bie n t tem perat ure and a i r v e l o ci t y @ v i n = 75v ( e i t her o r i entat i on, no h eat si nk ) 0 1 2 3 4 5 6 7 8 9 10 11 70 75 80 85 90 9 5 100 1 05 a m bi ent tem p eratu r e ( ) o u tpu t c u rren t (a ) nat u r a l convect i o n 100lfm 200lfm 300 lfm 400lfm 50 0lfm 60 0lfm h48 s v 3 r31 0 (s t a n d a r d) p o we r di ss ip at i o n vs . a m bi e n t te m p e r at ure an d a i r v e l o ci t y ( e i t he r ori e n t at i o n , n o he at si nk ) 0.0 0.8 1.6 2.4 3.2 4.0 4.8 5.6 70 75 80 85 90 95 1 0 0 105 a m bi ent t e m pera t ure ( ) p o w e r di ssi pati on (w att s ) natu r a l con v ec ti on 10 0lf m 20 0l f m 30 0l f m 400 lf m 5 00l fm 60 0l f m ds_h48sv3 r31 0_0 8152 006 8
ds_h48sv3 r31 0_0 8152 006 9 the input so urce must b e insulate d from the ac mains by reinforced or double insulation. the input terminals of the module are not operator acce ssi ble. if the metal base p late is g r oun ded , one vi pin and one vo pin sh all also b e ground ed. a selv reliability test is condu cted on the system whe r e th e m odule i s u s e d , in combin ation with th e module, to ensure that under a singl e fault, hazard o u s voltage doe s no t appear at th e module? s output. whe n install ed into a cla ss ii eq uipment (wit hout grou ndin g ), spaci ng co nsi deratio n sh o u ld be given to the end -u se installatio n , as the spa c in g betwe en t he module a nd mounting su rface h a ve not been eval uat ed. the po we r m odule h a s extra-l o w voltag e (elv) o u tp uts whe n all input s are elv. this p o wer module i s no t internally fused. to a c hi eve optimum safe ty and system prote c tion, a n input line fu se is highly re co mmend ed. t he safety ag enci e s requi re a norm a l-bl ow fuse with 20a maximu m rating to be installe d in the ungro und e d lead. a lower rated fuse can be u s ed ba se d on the m a ximum inrush tran sient e n e r gy and maximu m input cu rre nt. soldering and cleaning considerations post sold er cl eanin g is usu a lly the final board assem b ly pro c e ss befo r e the board or system und ergo es ele c tri c al testing. inade quate clea nin g and/or dryin g may lower the reliability of a power module and severely af fect the finishe d circui t board asse mbly test. adequate cl eani ng and/or dryin g is e s pe cially i m port ant for u n -en c a p sulat ed and/or ope n frame type po wer mod u les. for a s sist an ce on app rop r ia te solde r ing and cle ani ng procedu res, plea se cont a c t delt a? s technical su ppo rt team. design considera t ions input source impedance the imp eda n c e of the i n p u t sou r ce co nne cting to t h e dc/ dc po we r mod u le s wi ll intera ct wit h the mod u l e s and af fect the st ability . a low ac-i mpe d a n ce inp u t sou r ce is re comm en ded. if the source indu ct a n c e is mo re th an a few h, we advise addin g a 10 to 100 f electrolytic ca p a cit o r (e s r < 0. 7  at 100 khz) mounted close to the input of the module to i m prove the st ability . lay out and emc considerations delt a? s dc/ dc po we r mo d u les are de si gned to ope rate in a wide variety of system s and appli c at ions. for de si gn assist an ce with emc co mplian c e an d related p w b layout issu es, please cont act delt a? s te chni cal supp ort team. an ex ternal i nput f ilter mod u le is availa ble f o r easi e r emc compli an ce d e sig n . application note s to assist d e si gn ers in a d d r e s sing th ese i s sues are pe ndi ng relea s e. safet y considerations the po we r m odule m u st b e inst alled in compli an ce with the sp aci n g and se p a ration req u irement s of the end-user ? s safety agen cy st and ard, i.e., ul60 950, can/csa - c2 2.2 no. 6095 0-00 an d en6095 0:200 0 and iec6095 0-19 99, if the syst em in which the po wer module is to be used must meet safety agency requi rem ent s. basic i n sulat i on ba se d o n 75 vd c in put is p r ovid ed betwe en the input and o u tput of the module fo r the purp o se of a pplying in sul a tion re qui re ments wh en the input to this dc-to-dc co nverter i s ide n tified as t n v-2 or selv. an addition al evaluation i s neede d if the sou r ce is oth e r than t n v-2 or selv. whe n the in p u t sou r ce i s s e l v ci rcuit, the po wer mod u le meet s sel v (safety extra-low volt age ) requi rem ent s. if the input sou r ce i s a ha za rdou s volt age whi c h is grea ter than 60 vdc and less tha n or equal to 75 vdc, for the module? s out put to meet sel v requi re ment s, all of the following must be met:
fea t ures descriptions over-cu rre nt protection the modul es include a n internal o u tp ut over-curre nt prote c tion ci rcuit, whi c h will endure cu rrent limiting for an unlimited duration d u r ing outp u t overloa d . if the output curren t exceed s the ocp set poi nt, the modul es will automati c ally shut down (hiccup mode). the modules will try to restart after shutdown. if the overload condition still exi s ts , the module will shut down again. thi s restart trial wi ll continue u n til the overload con d ition is correcte d. over-v olt age protection the module s include an internal outp u t over-volt a ge prote c tion circuit, whi c h monitors the volt age on the output termin als. if this volt age exceed s the over-volt a ge set point, the module will shut do wn a nd latch of f. the over-volt age latch is reset by either cycling the in p u t power o r by togglin g the o n /of f signal fo r one second. over-t emp e rature pro t ection the over-te m perature protecti on con s ist s of ci rcuitry that provide s protectio n from thermal damag e. if the temperature excee d s the ov er-tem perature thresh old the module will shut do wn. the module will try to rest art af ter shut down. if the over-tem perature co ndition still exist s during rest art, the module will shut do wn again. thi s rest art trial will contin ue until the temperat ure is within specifi c ation. remote on /off the remote o n /off feature on the mo dul e ca n be eith er negative or positive logi c. negative logic tu rn s the module o n du ring a lo gic lo w and off du ri ng a logi c hig h . positive logi c turns th e m odule s on du ring a lo gic h i gh and off durin g a logic lo w. remote on/of f can b e cont rolled by an external swit ch betwe en the on/of f termin al and the v i (-) termi nal. the swit ch can be an open coll ector o r op en drain. for ne gative logic if the remote o n /of f feature is n o t use d , plea se sho r t the on /of f pin to v i (-). for positi v e logic if the remote on/of f feature is n o t used, pl e a se leave the on/ of f pin to floating. ds_h48sv3 r31 0_0 8152 006 10 vo(+) vi(+) vo(-) sense(-) sense(+) vi(-) on/off figure 2 0 : remote on/of f i m ple m ent atio n remote se nse remote sen s e comp en sat e s for volt ag e dro p s o n the output by sen s ing th e a c tu al output volt age at th e po int of load. the volt age bet wee n the re mote se nse pins and the outp u t terminals mu st not exceed the outp u t volt age sen s e rang e given here: [v o(+) ? v o (?)] ? [sense(+) ? sense(?)] 10% vo u t this limit includ es any increa se in volt age due to remote se nse co mpen sat i on an d outp u t volt age set point adju s tm ent (trim). vi(-) vi(+) vo(-) vo(+) sense(+) sense(-) resistance contact contact and distributio n losses figure 2 1 : ef fective circ uit c onfig uratio n fo r remote se ns e oper ation if the remote sen s e featu r e is not used t o regul ate the output at the point of loa d , plea se con n e c t sense(+) to v o (+) an d sense(? ) to v o (?) at the mo dule. the output volt age ca n be increa sed by both the remote sen s e and the trim; however , the maximum increa se i s th e larger of eit her th e remot e se nse o r th e trim, not the sum of both. whe n usi ng remote sen s e and trim, the output volt ag e of the mod u le is u s u a lly increa sed, whi c h incre a ses t he power outpu t of the mo dule with the same out put c u rrent. care sh ould be t a ken to ensu r e that the maximum output po we r doe s n o t e x ceed th e m a ximum rate d power .
ds_h48sv3 r31 0_0 8152 006 11 figure 2 3 : circuit config urati on for trim-u p (i ncreas e outp u t volt ag e) if the external resi stor i s co nne cted bet ween the t r im and sense (+) the output volt age set p o int incre a se s (fig. 23 ). the external re si stor valu e req u ired to obt ai n a percent a g e output volt a ge chan ge % is defined as: () kohm vo - ) (1 vo vo ) (1 vo 66 . 0 up rtrim ? ? + + + = ? ex. when t r i m -up +10% (3 .3v1.1 = 3.63 v) () kohm up rtrim 26 . 17 3.3 - ) 1 . 0 (1 3.3 3 . 3 ) 1 . 0 (1 3 . 3 66 . 0 = + + + = ? the o u tput vo lt age can be i n crea sed by both the rem o te sen s e a nd th e trim, howe v er the maximum increa se is the larger of either th e re mote sen s e o r the tri m , not the sum of both. whe n usi ng remote sen s e and trim, the output volt a ge of the module is usually i n cr ea sed, wh ich in crea se s the power outpu t of the module with the same out put c u rrent. care sh ould be t a ken t o ensure th at the maximum output power of the module remain s at or below the maximum rat ed power . fea t ures descriptions (con.) output v o lt age adjustment (trim) to in cre a se or d e crea se the outp u t vol t age set poi n t, the modul es may be conne cted wit h an extern al resi sto r bet wee n the trim pin and eithe r the sense(+ ) or sense(-). the trim pin sho u ld be left open if this fe ature is n o t used. figure 2 2 : circuit configur a t ion for trim-d ow n (decreas e output volt a ge) if the external resi stor i s co nne cted bet ween the t r im and sense (-) pin s , the output vol t age set poi nt decrea s e s (fig. 22). t he extern al resi stor va lue requi re d to obt ain a percent age of output volt ag e cha nge % is define d as: () kohm down rtrim ) (1 vo 3 . 3 vo - ) (1 vo 2 ? ? ? ? ? = ? ex. when t r i m -do w n -20 % (3.3v0.8 = 2.64v) () kohm down rtrim 3 ) 2 . 0 (1 3 . 3 3 . 3 3.3 - ) 2 . 0 (1 3 . 3 2 = ? ? ? = ?
thermal consi d era t i o ns therm a l man ageme n t is a n importa nt part of the syst em desi gn. to e n su re p r op er, reliabl e ope ration, suffici e n t cooli ng of th e po we r mod u le is nee de d over th e e n tire temperature range of the modul e. co n v ection co olin g is usu a lly the dominant mo d e of heat tran sfer. hen c e, the choi ce of eq uipment to chara c te rize the thermal p e rf orma nce of the po wer m odule i s a wind tunnel. thermal t esting setup delta? s dc/ dc po we r module s are chara c te rize d in heated verti c al wind tunn els t hat simu late the thermal environ ment s encou ntered in most electroni cs equipm ent. this type of equipm ent comm only u s e s vertically mou n ted circuit card s in cabi n e t rac ks in w h ich the power mo dule s are m o unted. the followi ng figure shows the wind tunnel cha r a c teri zati on setup. th e powe r mod u le is mount ed on a test pwb and is vertically po sitioned within the wind tun nel. the sp a c e b e twee n the neighb orin g pwb and the top of the power modul e i s const antly ke p t at 6.35mm (0.2 5? ?). n o t e : w i nd t unne l t e s t s e t up fi gur e d i mens i ons a r e i n m i l l i m e t e r s and ( i nc he s) 1 2 .7 ( 0 . 5 ?) mo du l e a ir f l o w 50. 8 ( 2. 0 ? ) f a ci ng p w b pw b ai r ve l o ci t y an d ambi e n t t e mper at u r e me asu red b e lo w th e m o d u l e figure 2 4 : w i nd tunne l test setup thermal derating heat ca n be removed by incr ea sin g airflow over the module. th e module? s maximum ca se temperature is +10 0 c. t o enhan ce system reli a b ility , the p o we r module sh oul d always b e operated b e l o w the m a ximum operating te mperature. if the tempera t ure exce ed s the maximum module tempera t ure, reliabilit y of the unit may be af fected. ds_h48sv3 r31 0_0 8152 006 12
mechanical dra w ing pin no. name function 1 2 3 4 5 6 7 8 9 -v in case on/off +v in + v out +sense tr i m -sense -v out neg a tive in put volt ag e case grou nd remote on/off positive i nput v o lt ag e positive o u tput volt age positive remote sense output volt age trim neg a tive remot e sense neg a tive o u tpu t volt age pin s pecification: pins 1-4, 6-8 1.02mm ( 0.04 0 ? ) diameter pins 5 & 9 2.00mm (0.0 79?) di ameter all pi ns are co pper w i t h t i n pl ating. ds_h48sv3 r31 0_0 8152 006 13
p a rt numbering system h 4 8 s v 3 r 3 1 0 n r f a form f acto r inpu t v o lt ag e number of outp ut s produc t series outp ut vo l t a g e outp ut current on/off logic pin le n g th optio n co de h- half brick 48v s- single v - v a l ue line 3r3- 3.3v 10- 10a n- nega tive p- positive r- 0.170 ? n- 0.145 ? k- 0.1 1 0 ? f- ro hs 6/6 (lead f r ee ) a- s t andard fun c tions model list model name input outp ut eff @ 100 % load h48sv3r310 nr f a 3 6 v ~ 7 5 v 1 . 3 a 3 . 3 v 1 0 a 89.5% h48sv3r320 nr f a 3 6 v ~ 7 5 v 2 . 5 a 3 . 3 v 2 0 a 90.0% h48sv3r330 nr f a 3 6 v ~ 7 5 v 3 . 7 a 3 . 3 v 3 0 a 90.5% h48sv3r340 nr f a 3 6 v ~ 7 5 v 4 . 9 a 3 . 3 v 4 0 a 89.5% h48sv05010n r f a 3 6 v ~ 7 5 v 1 . 9 a 5 . 0 v 1 0 a 88.5% h48sv05020n r f a 3 6 v ~ 7 5 v 3 . 7 a 5 . 0 v 2 0 a 90.0% h48sv05030n r f b 3 6 v ~ 7 5 v 5 . 5 a 5 . 0 v 3 0 a 9 0 . 5 % default remote o n /of f logic is neg ative and pin length is 0.170? for dif f erent rem o te on/of f logic and pin length, ple a se refer to p a rt numbering s y ste m above or cont act y our local sales c o nt ac t : www . d elt a .com.t w / dcdc us a : t e lepho ne: east coast: (888) 33 5 82 01 w e st coast: (888) 33 5 82 08 f a x: (97 8 ) 656 396 4 email: dcd c @ delt a -c orp.co m europe : phon e: + 41 31 998 5 3 1 1 f a x: + 41 31 9 9 8 53 53 email: dcdc@delt a - e s.com a s i a & the re st of w o r l d: t e lepho ne: + 8 86 3 45 26 10 7 ext 6 220 f a x: + 886 3 4 5 134 85 email: dcd c @ delt a .com.t w w arra nt y delt a of fers a two (2) year limited warrant y . complete warranty information is list ed on our web site or i s available u pon requ est from delt a. information fu rnished by delt a is beli e ve d to be accu rate and re li ab le. ho weve r , no respon sibi lity is assum e d by delt a fo r it s use, no r for a n y infringem e n t s of p a tent s or othe r righ t s of thir d p a rti e s, whi c h m a y result from i t s u s e. no li cense is g r ant e d by implication or otherwise unde r any p a tent or p a tent right s of delt a. delt a re se rves the right to revise the s e spe c ificatio ns at any time, without noti c e . ds_h48sv3 r31 0_0 8152 006 14


▲Up To Search▲   

 
Price & Availability of H48SV05030NRFB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X